Innovation Skid Packaged Systems

AERCO’s packaged skid systems simplify project planning by integrating our highly efficient boilers or water heaters with all required pumping and piping so customers receive a fully assembled system that saves installation time, lowers construction costs and delivers superior performance. Having a complete engineered system in one convenient package designed and assembled by AERCO not only reduces your project time-lines by getting all equipment from one trusted source, but also gives you the confidence knowing you’ll be installing an entire system built of the highest quality. There’s also an optional weather-proof external enclosure for full skid available for those who want to install a plant outdoors.

Features and Benefits

  • Expertly designed from a single source – Hand-built by skilled craftsmen with decades of experience in water heating designs, each system operates to the highest efficiency and reliability for the best possible return on investment, eliminating system maintenance and repairs due to improper assembly
  • Cost-efficient – Systems lower installation costs, reduce project time-lines, increase ROI, and provide higher long-term operational benefits
  • Compact – Featuring a small footprint, the packaged systems can be used in new construction or retrofits with limited space
  • Customizable – Systems are customized for each application and can be assembled to satisfy a variety of load requirements or include enclosures for systems installed outdoors including rooftops
  • Guaranteed – AERCO stands behind every system with 100% confidence; operation is verified by factory startup testing before it is shipped

Options and Accessories

Product Options

Standard Water Heater Modules
Available in either two, three or four water heaters configuration with WHM sequencing valves. Multiple water heater modules can be easily installed and assembled together to meet additional units’ requirement.

Pumps modules
Available to meet system capacity requirements which can be easily assembled with water heater modules.

Indoor/Outdoor Installation
Enclosures available for outdoor installations of water heaters and pump modules. Modules available without enclosures for indoor installations. Following three enclosures options available for outdoor installations of water heaters and pump modules:

  • Standard High end option of a full walk-in metal building with insulation and State certification.
  • Fiberglass enclosure.
  • Cost-effective metal enclosure standard un-insulated. Available with R-10 insulation if requested.

Consult factory for more information regarding these options. Modules available without enclosures for indoor installations.

Gas Header Size(s)
Depending upon field and total system capacity requirement.

Hot Water Supply and cold water inlet Header Sizes
Depending upon total system flow requirements.

AERCO Condensate Neutralizer Kit
The Condensate Neutralizer Kit is included in all boilers module options – either capsule or tank models selected based upon BTU capacity requirement.

Custom Engineered Packages
Custom design package solutions are available to meet specific field requirements.


Accessories

AERCO Scale Reducer
A must have accessory for installations in areas with hard water (>3.5 grains/gal). It provides an economical, maintenance free treatment of hard water without the use of salt or any chemicals. The SR300 prevents new scale build-up and eliminates existing build-up in water heaters, boilers and storage tanks, hot water piping, valves, recirculation lines and pumps, mixing valves, showerheads and other plumbing fixtures.

Communications Gateway
Optional accessory supports heater communication with your facilities BACnet, LonWorks and N2 systems.

Domestic Water Storage Tank
AERCO storage tanks are ASME certified glass-lined pressure vessels designed for use with instantaneous water heaters. When contending with challenging applications they assure consistent hot water service during peak demands. The AERCO storage tanks are available in stratified or accumulator storage configurations.

Gas Supply Regulator

  • Non-lock-up regulators for gas pressure < 14" W.C.
  • Lock-up regulators for gas pressures > 14" W.C.

Zero-side Clearance Kit
When two units are installed side by side, this kit covers the gap between the equipment – maintaining the air intake plenum functionality of the enclosure.

Technical Documents

Installation and Piping Drawings

Innovation 2 Units Skid Package Clearance Drawing (SD-A-1129)

DWG 770.6 KB | November 11, 2016

Innovation 2 Units Skid Package Clearance Drawing (SD-A-1129)

PDF 123.86 KB | November 11, 2016

Innovation 3 Units Skid Package Clearance Drawing (SD-A-1130)

DWG 906.05 KB | November 11, 2016

Innovation 3 Units Skid Package Clearance Drawing (SD-A-1130)

PDF 141.26 KB | November 11, 2016

Innovation 4 Units Skid Package Clearance Drawing (SD-A-1131)

DWG 1.04 MB | November 11, 2016

Innovation 4 Units Skid Package Clearance Drawing (SD-A-1131)

PDF 151.95 KB | November 11, 2016

Product and Component Drawings

Innovation 2 Units Skid Package (SD-A-1108)

dwg 2.03 MB | October 11, 2016

Innovation 2 Units Skid Package (SD-A-1108)

pdf 294.59 KB | October 11, 2016

Innovation 3 Units Skid Package (SD-A-1127)

dwg 2.68 MB | October 11, 2016

Innovation 3 Units Skid Package (SD-A-1127)

pdf 362.88 KB | October 11, 2016

Innovation 4 Units Skid Package (SD-A-1128)

dwg 6.55 MB | October 11, 2016

Innovation 4 Units Skid Package (SD-A-1128)

pdf 439.4 KB | October 11, 2016

Specifications

Innovation Skid Package Specifications

doc 102.5 KB | November 29, 2016