AMR (AM Rapid Recovery)

The AMR (Advanced Modular Rapid Recovery) water heaters provide a complete water heating solution in one convenient package. With integrated thermal buffer, pump, and required piping, the AMR series is the easiest solution for domestic water heating from 199 to 1000 MBTUs. All of the great features of the AM Series remain, from the built-in redundancy to the small footprint. The AMR is ready for fast installation to get your domestic water heating plant up and running quickly. Multiple units can be located with near-zero side clearance for even larger installations. The AMR is available in two styles: Integrated in a single package or skid mounted with selectable tank and optional AERCO SR300 Scale Reducing System.

The AMR ships ready to be piped into a domestic water heating system to provide hot water immediately. A mixing valve can be supplied as an accessory for a complete water heating solution. The AMR is great for new construction to save space as well as for replacement of existing equipment; all sizes fit through a standard doorway. As with all AERCO boilers and water heaters, high efficiency and low emissions are hallmark features to provide the best performance for your system.

Features and Benefits

  • From 199 to 1000 MBTU's
  • High efficiency condensing water heater
  • Natural gas or propane
  • Superior turndown means low operating cost and tight temperature control
  • Complete heating plant in one package
  • Direct or conventional vent with PVC, cPVC, Polypropylene, or AL29-4C
  • Concentric vent capability
  • Common vent capability
  • Unparalleled reliability
  • Minimal maintenance
  • Small footprint saves space and makes retrofits a breeze
  • Easy front access for serviceability
  • Low NOx <20ppm
  • Supports integration to BAS System
  • Modbus communication standard

Options and Accessories

Installation Kits (Application Specific)

  • Gas Installation Kit – Gas Regulator, Pipe Union, Isolation Ball Valve, applicable coupling/bushing
  • Communication Board (modbus) for AM 250R and AM 199R

AERCO Digital Mixing Station (ADMS)
Lead-free, ASSE 107 certified ADMS is a smart water tempering system that allows temperature controlled distribution of potable hot water throughout the loop. The building automation system (BAS) ready ADMS™ can be configured with strainers, building recirculation pump and Flow/BTU monitor package to allow facilities managers to remotely monitor and control distribution water temperatures along with monitoring of flow and energy consumption.

Communications Gateway
Optional accessory supports heater communication with your facilities BACnet, LonWorks and N2 systems.

Contractor Kit
Includes all the spare parts necessary to service and maintain the unit, including control board, igniters, flame rods, and all the screws, nuts and gaskets.

Hydroskrub
A liquid descaler specifically designed to dissolve all water scale, lime, mud, rust, and other water-formed deposits from water operated equipment and systems

Technical Documents

Application and Sizing Guidelines

AM SERIES Electrical Power Guide (GF-146-E)

pdf 1.07 MB | December 14, 2015

AM SERIES Gas Supply Application Guide (GF-146-G)

pdf 308.06 KB | December 14, 2015

AM SERIES Piping Application Guide (GF-146-P) (TAG-0074)

pdf 3.39 MB | August 14, 2017

AM Series Venting Application Guide (GF-146-V) (TAG-0075)

pdf 1.12 MB | December 1, 2017

AM Series Water Heater Primary Loop Design Guide

pdf 123.44 KB | June 23, 2016

Installation and Piping Drawings

AMR 199-500 Integrated Style Installation Clearances (AP-A-1017)

pdf 68.88 KB | January 21, 2016

AMR 199-500 Integrated Style Installation Clearances (AP-A-1017)

dwg 625.28 KB | April 11, 2016

AMR 199-500 Integrated Style Multi Unit Installation (SD-A-1075)

pdf 273.7 KB | April 20, 2016

AMR 199-500 Integrated Style Multi Unit Installation (SD-A-1075)

dwg 3.88 MB | April 20, 2016

AMR 199-500 Integrated Style Multi-Unit Installation Clearances (AP-A-1018)

pdf 66.05 KB | January 21, 2016

AMR 199-500 Integrated Style Multi-Unit Installation Clearances (AP-A-1018)

dwg 613.53 KB | April 11, 2016

AMR 199-500 Integrated Style Single Unit Installation (SD-A-1074)

pdf 139.24 KB | April 20, 2016

AMR 199-500 Integrated Style Single Unit Installation (SD-A-1074)

dwg 2.81 MB | April 20, 2016

AMR 399-500 Skid Style Multi Unit Installation (SD-A-1070)

pdf 1.15 MB | January 21, 2016

AMR 399-500 Skid Style Multi Unit Installation (SD-A-1070)

dwg 3.87 MB | April 11, 2016

AMR 399-500 Skid Style Multiple Installation Clearances (AP-A-1015)

pdf 711.03 KB | January 21, 2016

AMR 399-500 Skid Style Multiple Installation Clearances (AP-A-1015)

dwg 1.26 MB | April 11, 2016

AMR 399-500 Skid Style Single Installation Clearances (AP-A-1014)

pdf 489.62 KB | January 21, 2016

AMR 399-500 Skid Style Single Installation Clearances (AP-A-1014)

dwg 855.46 KB | April 11, 2016

AMR 399-500 Skid Style Single Unit Installation (SD-A-1069)

pdf 736.23 KB | January 21, 2016

AMR 399-500 Skid Style Single Unit Installation (SD-A-1069)

dwg 3.24 MB | April 11, 2016

AMR 750-1000 Skid Style Installation Clearances (AP-A-1011)

pdf 582.23 KB | January 21, 2016

AMR 750-1000 Skid Style Installation Clearances (AP-A-1011)

dwg 863.83 KB | April 11, 2016

AMR 750-1000 Skid Style Multi Unit Installation (SD-A-1068)

pdf 1.34 MB | January 21, 2016

AMR 750-1000 Skid Style Multi Unit Installation (SD-A-1068)

dwg 7.42 MB | April 11, 2016

AMR 750-1000 Skid Style Multiple Installation Clearances (AP-A-1012)

pdf 783.11 KB | January 21, 2016

AMR 750-1000 Skid Style Multiple Installation Clearances (AP-A-1012)

dwg 1.36 MB | April 11, 2016

AMR 750-1000 Skid Style Single Unit Installation (SD-A-1067)

pdf 887.61 KB | January 21, 2016

AMR 750-1000 Skid Style Single Unit Installation (SD-A-1067)

dwg 3.4 MB | April 11, 2016

AMR Series Integrated Style ADMS Mult Unit Installation (SD-A-1144)

dwg 7.09 MB | April 25, 2017

AMR Series Integrated Style ADMS Mult Unit Installation (SD-A-1144)

pdf 287.71 KB | April 25, 2017

Multi-unit AMRI with ADMS and OneFlow (SD-A-1150)

pdf 263.99 KB | July 11, 2017

Multi-unit AMRI with ADMS and OneFlow (SD-A-1150)

dwg 5.67 MB | July 11, 2017

Literature and Performance Data

AERCO AM Series Brochure

pdf 6.25 MB | December 12, 2017

AERCO AM Series Metric Brochure

pdf 6.25 MB | December 12, 2017

AERCO AMR Series Technical Data Sheet

pdf 930.83 KB | October 24, 2017

AM Altitude Derate C302.7

pdf 42.36 KB | December 14, 2015

AM-Part-Load-Efficiency

pdf 57.28 KB | January 21, 2016

Operation and Maintenance Manuals (O&M)

AM Series Modbus Interface Manual (OMM-0102) (GF-146-MB)

pdf 361.49 KB | December 30, 2016

AM Series User Manual (OMM-0100) (GF-146)

pdf 16.28 MB | December 30, 2016

AMRI Supplement to User Manual GF-146 (OMM-0106) (GF-146-IR)

pdf 4.69 MB | December 30, 2016

Product and Component Drawings

AMR 199-500 Integrated Style Dimensional Drawing (AP-A-1016)

dwg 2.84 MB | June 28, 2016

AMR 199-500 Integrated Style Dimensional Drawing (AP-A-1016)

pdf 230.13 KB | June 28, 2016

AMR 399-500 Dimensional Drawing (AP-A-1013)

pdf 179.01 KB | June 29, 2016

AMR 399-500 Dimensional Drawing (AP-A-1013)

dwg 2.17 MB | June 29, 2016

AMR 750-1000 Dimensional Drawing (AP-A-1010)

dwg 2.5 MB | June 28, 2016

AMR 750-1000 Dimensional Drawing (AP-A-1010)

pdf 183.41 KB | June 28, 2016

AMR Water Heater 199-500 Revit Drawings

rfa 600 KB | September 27, 2016

AMR Water Heater 399-500 Revit Drawings

rfa 624 KB | September 27, 2016

AMR Water Heater 750-1000 Revit Drawings

rfa 700 KB | September 27, 2016

Specifications

AMR Integrated Specifications

doc 64.5 KB | January 21, 2016

AMR Skid Specification

doc 64.5 KB | January 21, 2016

Warranty

C105-01-AMR-Warranty

pdf 109.55 KB | January 21, 2016

Case Studies