AERCO Digital Mixing Station (ADMS)

The AERCO Digital Mixing Station (ADMS™) is a smart water tempering system that allows temperature controlled distribution of potable hot water throughout the loop. The lead-free1 ADMS™ regulates distribution temperature within ±2ºF in accordance to ASSE 1017 at all flow conditions (including low and zero demand periods) and its temperature setting is field configured without the use of special software and laptop.

The building automation system (BAS) ready ADMS™ can be configured with strainers, building recirculation pump and Flow/BTU monitor package to allow facilities managers to remotely monitor and control distribution water temperatures along with monitoring of flow and energy consumption. Unlike the traditional thermostatic mixing valves, it is capable of functioning under varying pressure differentials across the inlets.The ADMS when paired with an AERCO water heater provides a fully integrated and proven solution from a common manufacturer for safe and reliable hot water distribution.

Features and Benefits

If local code mandates use of a mixing valve or for storage tank or two temperature applications with AERCO water heaters, it is recommended to use ADMS™.

  • Configurable on site without special software and laptop
  • Tight temperature control of ±2ºF in accordance with ASSE 1017
  • Control ±2°F during periods of low/zero demand
  • 3.5” full-color, user-selectable touch screen display
  • User programmable high-temperature sanitization mode
  • Cold water failsafe with manual override feature to set mixed outlet temperature
  • Settings can be adjusted/monitored at the controller or remotely via BACNET or Modbus interface
  • Displays pressure, temperature and flow/BTU data
  • Pass code protected for security
  • User programmable high temperature alarm

Options and Accessories

ADMS™ can be ordered in a variety of different configurations depending on the application and desired options. The valve size, valve quantity and building recirculation pipe size can be derived from the application flow rate and acceptable pressure drop. The building recirculation pipe size can be selected to be 1” return or 2” return for single valve configurations. For double or triple valve configurations, the building recirculation pipe size is 3”.

The Flow/BTU monitoring package, strainers and building recirculation pump options can be individually selected. When choosing the recirculation pump, the following information must be furnished to AERCO: Pump Manufacturer, Manufacturer Model and Part Number, System Head Loss and required Flow to maintain Recirculating Temperature.

Technical Documents

Installation and Piping Drawings

AM Series ADMS Stratified Tank Multi Unit Installation DWH (SD-A-1143)

dwg 4.98 MB | April 25, 2017

AM Series ADMS Stratified Tank Multi Unit Installation DWH (SD-A-1143)

pdf 287.38 KB | April 25, 2017

AMR Series Integrated Style ADMS Mult Unit Installation (SD-A-1144)

dwg 7.09 MB | April 25, 2017

AMR Series Integrated Style ADMS Mult Unit Installation (SD-A-1144)

pdf 287.71 KB | April 25, 2017

Innovation Seq Valve ADMS Mult Unit (SD-A-1141)

dwg 3 MB | April 25, 2017

Innovation Seq Valve ADMS Mult Unit (SD-A-1141)

pdf 249.41 KB | April 25, 2017

Innovation Seq Valve ADMS Multi Unit Stratified Tank (SD-A-1142)

dwg 3.19 MB | April 25, 2017

Innovation Seq Valve ADMS Multi Unit Stratified Tank (SD-A-1142)

pdf 254.31 KB | April 25, 2017

SmartPlate Single Unit ADMS Installation with Storage Tank (SD-A-1148)

pdf 217.89 KB | June 16, 2017

SmartPlate Single Unit ADMS Installation with Storage Tank (SD-A-1148)

dwg 2.82 MB | June 16, 2017

Instructions

ADMS User Guide and Instruction Manual

pdf 2.54 MB | May 4, 2017

Literature and Performance Data

AERCO ADMS Brochure

pdf 2.25 MB | October 19, 2017

AERCO ADMS Technical Data Sheet

pdf 937.04 KB | May 25, 2017