Innovation 1060
OVERVIEW

Innovation 1060

Once again, AERCO leads the way in commercial water heating technology with the introduction of Innovation, its newest line of premium water heaters. Featuring a tankless design, advanced condensing & modulating technology, and a scale-resistant heat exchanger, Innovation delivers performance and economic advantages to any system.

Click here to see the Innovation Product Video

Click here to launch the NEW AERCO SMART SIZE Water Heater Selection Program

• Up to 99% efficiency
• +/-4° temperature control, thanks feed-forward sensing and unmatched turndown
• High reliability
• Small footprint due to its tankless design
• Reduced standby and cycling losses
• Low NOx
Efficiencies up to 99%
The AERCO Innovation Water Heater utilizes state-of-the-art technology to easily meet highly diverse, demanding commercial and industrial hot water requirements in a compact and reliable condensing design. The durable, high efficient, helical firetube heat exchanger is time tested to be impervious to thermal stress for an extended life. The all stainless steel construction maximizes longevity in the condensing application and the corrugated tubes increase effective heat transfer surface area for optimal thermal efficiencies up to 99%. Enhanced waterside flow distribution maintains constant minimum velocities across the heat exchanger; this keeps solids in suspension and greatly reduces scale dropout to maintain high-efficiency performance and long life.
 
Precise Temperature Control and up to 20:1 Turndown Delivers Money-Saving Precision
The advanced control system incorporates dynamic feed-forward sensing for precise modulation of its high turndown air/fuel delivery system. These controls fire the unit to accurately match load requirements and produce a tight hot water outlet temperature control. With up to 20:1 turndown, the AERCO Innovation takes maximum advantage of its thermal efficiency, eliminating wasted fuel and reducing operating costs.
 
Commercial Tankless Design:
The unique tankless design gives the ability to operate the system with set points of 120°F or below – saving energy and reducing the risk of scalding.  Minimal water volume and maintaining continuous circulation through the unit virtually eliminate the risk of Legionella bacteria growth.
 
Venting Versatility:
Sidewall, through–the–roof, and sealed combustion capabilities provide broad installation flexibility and savings.
 
Space-Saving Design:
The AERCO Innovation is delivered as a single, fully assembled unit. Its small foot print, doorway size, and quiet operation make it ideal for both new construction and retrofit applications.
Product Options
Double Block and Bleed Gas Train (formly IRI) - Incorporates two safety shut-off valves in a single valve body with normally open vent valve.

Reduced NOx Level- AERCO recommended calibration points can be re-set to support applications that require reduced NOx emissions level of <9ppm. However, the unit's input rate, performance efficiency and venting requirements will change. Please consult the factory for assistance balancing your efficiency and environmental requirements.
ACCESSORIES
Domestic Water Storage Tank- AERCO storage tanks are ASME certified glass-lined pressure vessels designed for use with instantaneous water heaters. When contending with challenging applications they assure consistent hot water service during peak demands. The AERCO storage tanks are available in stratified or accumulator storage configurations.

Gas Supply Regulator-
·    Non-lock-up regulators for gas pressure < 14" W.C.
·    Lock-up regulators for gas pressures > 14" W.C.

Communications Gatewayoptional accessory supports heater communication with your facilities BACnet, LonWorks and N2 systems.

AERCO Condensate Neutralizer Kit- is ideal for neutralizing condensate from condensing boilers and furnaces operating on natural gas or propane.

AERCO Scale Reducer- A must have accessory for installations in areas with hard water (>3.5 grains/gal). It provides an economical, maintenance free treatment of hard water without the use of salt or any chemicals. The SR300 prevents new scale build-up and eliminates existing build-up in water heaters, boilers and storage tanks, hot water piping, valves, recirculation lines and pumps, mixing valves, showerheads and other plumbing fixtures.
 
Literature & Performance Data
File Type View Save File Type View Save
C-More Tech Data Sheet .pdf
Water Side Pressure Drop and Velocity (D310.0) .pdf
Altitude DeRate Factors D300.0 .pdf
Emissions Data D601.0 .pdf
Innovation Family Brochure .pdf
Innovation Water Heater Management (WHM) Technical Data Sheet .pdf
Innovation Series Technical Data Sheet .pdf
Sizing & Application Guidelines
File Type View Save File Type View Save
Innovation/ ReCon Gas Supply Guide (GF-5030) .pdf
Innovation/ ReCon Venting Guide (GF-5050) .pdf
Innovation / ReCon Power Guide (GF-5060) .pdf
Innovation Laundry Sizing Guide (GF-5080) .pdf
Innovation Sizing Guidelines .pdf
Plumbing Fixture Unit Selection Tool.xlsx .xlsx
Instructions
File Type View Save File Type View Save
Innovation 12 Month Maintenance Kit (58036 1-3) .pdf
Innovation 24 Month Maintenance Kit (58036-2-4) .pdf
INN HX Baffle Retrofit Kit .pdf
Product & Component Drawings
File Type View Save File Type View Save
Condensate Trap Assembly (AP-A-814) .pdf .dwg
Bill of Materials - Air/Fuel Delivery System (PL-A-164) .PDF
Bill of Materials - Burner Intake Manifold (PL-A-165) .PDF
Bill of Materials / Part List (PL-A-167) .PDF
Gas Trains            
Standard FM (AP-A-896) .PDF
Double Block & Bleed / IRI (AP-A-897) .PDF
Supply Gas Regulators            
Jeavons J48 1 1/2" NPT 14" to 20" WC Inlet Pressure (SD-A-629) .pdf .dwg
Jeavons J48 1 1/4" 20" WC to 1.5 PSI Inlet Pressure (SD-A-630) .pdf .dwg
Jeavons J48 1" NPT 1.5 to 2.0 PSI Inlet Pressure (SD-A-631) .pdf .dwg
Maxitrol RV-81 9" to 14" WC inlet pressure (SD-A-641) .pdf .dwg
Dimensional Drawings            
Innovation Water Heater (AP-A-888) .pdf .dwg
Dimensional with Water Heater Sequencing Valve (AP-A-902) .pdf .dwg
3D Models            
Revit Solid 3-D Model INN1060 .rfa
Innovation Revit Drawings .rfa
Innovation with Sequencing Valve Revit Drawing .rfa
Valves            
Temperature & Pressure Relief Valve (AP-A-890) .PDF .DWG
2" Domestic Hot Water Ball Valve (SD-A-918) .pdf
Installation & Piping Drawings
File Type View Save File Type View Save
Clearance for Standalone Unit Placement (SD-A-834) .pdf .dwg
Clearance for Side-by-Side Unit Placement (SD-A-835) .pdf .dwg
Single Heater            
Single Unit Installation (SD-A-829) .pdf .dwg
Stratified Storage Tank Installation (SD-A-830) .pdf .dwg
Stratified Peak Storage Tank for 2 Temperature Zone Installation (SD-A-831) .pdf .dwg
Single Unit Installation with 2 Temperature Zones (SD-A-845) .pdf .dwg
Multiple Heater            
Multiple Unit Installation (SD-A-832) .pdf .dwg
Installation with Stratified Storage Tank (SD-A-833) .pdf .dwg
Installation with 2 Temperature Zones (SD-A-836) .pdf .dwg
Installation with Stratified Storage Tank and 2 Temperature Zones (SD-A-837) .pdf .dwg
Two Zero Side Clearance and 1 Separate (SD-A-838) .pdf .dwg
Two Pairs with Zero Side Clearance (SD-A-841) .pdf .dwg
Two Pairs with Zero Side Clearance and Stratified Storage Tank (SD-A-842) .pdf .dwg
Two Pairs with Zero Side Clearance and 2 Temperature Zones (SD-A-843) .pdf .dwg
Two Pairs with Zero Side Clearance, 2 Temperature Zones and Stratified Storage Tank (SD-A-844) .pdf .dwg
Multiple Unit Installation with Sequencing Valves (SD-A-848) .pdf .dwg
Installation with Stratified Storage Tank and Sequencing Valves (SD-A-849) .pdf .dwg
Installation with Stratified Storage Tank and 2 Temperature Zones w/ Sequencing Valves (SD-A-850) .pdf .dwg
Two Zero Side Clearance and 1 Separate with Sequencing Valves (SD-A-851) .pdf .dwg
Two Pairs, Zero Side Clearance with Sequencing Valves (SD-A-852) .pdf .dwg
Two Pairs with Zero Side Clearance and Stratified Storage Tank with Sequencing Valves (SD-A-853) .pdf .dwg
Two Pairs with Zero Side Clearance, 2 Temperature Zones and Sequencing Valves (SD-A-854) .pdf .dwg
Two Pairs with Zero Side Clearance, 2 Temperature Zones, Stratified Storage Tank and Sequencing Valves (SD-A-855) .pdf .dwg
Two Pairs with Zero Side Clearance, 2 Temperature Zones and Sequencing Valves (SD-A-856) .pdf .dwg
Two Zero Side Clearance and 1 Seperate Two Temperature Zones and Sequencing Valves (SD-A-939)
Two Unit Installation and Sequencing Valves (SD-A-941) .pdf .dwg
Two Unit Installation with Stratified Storage and Sequencing Valves (SD-A-940) .pdf .dwg
Two Zero Side Clearance and 1 Seperate with Stratified Storage Tank and Sequencing Valves (SD-A-964) .pdf .dwg
Controls
File Type View Save File Type View Save
C-More Wiring Diagram - BAS to C-More (SD-A-659) .pdf .dwg
C-More Wiring Diagram- Water Heater Management (SD-A-878) .pdf
Specifications
File Type View Save File Type View Save
Natural Gas CI Specification .doc
Propane CI Specification .doc
Dual Fuel with WHM Spec .doc
Certifications/Approvals
File Type View Save File Type View Save
SCAQMD Approval Letter .pdf
INNOVATION Efficiency Letter .pdf
Warranty
File Type View Save File Type View Save
Innovation Limited Warranty .pdf
 
Operation & Maintenance
File Type View Save File Type View Save
Innovation GF-128 O&M Manual (G-12-1152_and UP) .pdf
Innovation GF-128 O&M Manual (G-10-1350 to G-11-0563) .pdf
Innovation O&M Manual- French Version (GF-128) .pdf
C-More Control Panel (GF-112) 4.22.2014 .pdf
 
Title Industry Products
For this university, it was an amazing lesson in energy-efficient economics Education Innovation 1060, Benchmark 3000
This university gets smart on case study efficiency and controlling costs Education Innovation 1060, Benchmark 3000
For better efficiency, this school district did its homework Education Innovation 600, Innovation 800, Innovation 1060, Innovation 1350, Benchmark 6000, AERCO 500-gallon storage tank
Giving an old school a new case study education in efficiency Education, K-12 Innovation 600
How this governor’s mansion became an official example of efficiency Government Innovation 1060
Finding a healthy and efficient solution for a hospital with growing pains Healthcare Innovation 1060
For this new hospital’s water heating needs, it was all about finding the right remedy Healthcare Innovation 1350
Meeting a big healthcare facility’s needs— in the smallest way Healthcare Innovation 600, Innovation 800, Benchmark 3000
For this eldercare facility, we turned an aging system into a model of efficiency Healthcare/Nursing home Innovation 1060, Benchmark 2000
Finally, the ideal retrofit for this hotel Hotel Innovation 1060 
Helping a hotel overcome its inherited inefficiency Hotel Innovation 800
Whenever this major hotel case study upgrades, it asks for AERCO Hotel Innovation 1060, KC1000
Turning a sky-high, inefficient problem into an energy-saving solution Offices Innovation 600
A luxury high-rise doesn’t have case study to mean high installation costs Residential Innovation 1060, Benchmark 3000
This arena’s hot water issues were leaving employees and players cold Sports and entertainment Innovation 1060
 

Send to a Colleague
Your name:
Colleague's E-mail:
Your message (click here):