init
Project
LOGIN
Superintendents
Chancellors
Head Masters
Facilities / Property Managers
Architects
Engineers
Contractors
Directors
Facilities / Property Managers
Architects
Engineers
Contactors
Procurement Managers
Project Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Owners
Facilities / Property Managers
Architects
Engineers
Contractors
Owners
Facilities / Property Managers
Architects
Engineers
Contractors
General Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Procurement Managers
Port Engineers
Ship's Crew
Architects
Engineers
Contractors
Owners
Project Managers
Facilities / Property Managers
Architects
Engineers
Contractors
Education
Healthcare
Government
Hotels & Apartments
Office Buildings
Industrial & Manufacturing
Navy & Marine
Other
Benchmark 750 & 1000
Benchmark 1.5 Low NOx Boiler
Benchmark 2.0 Low NOx Boiler
Benchmark 3000
Benchmark 6000
Esteem 399 Low NOx Wall Hung Boiler
Benchmark
Esteem Boilers
Modulex Boilers
Water-Wizard B+II
A+ (Model #SW1A+)
B+ (Model #SW1B+)
E+ (Model #WW3E+)
Innovation 600
Innovation 800
Innovation 1060
Innovation 1350
Single Wall
Double Wall
Model #SWDW24
Model #SWDW45
Model #SWDW68
Model #WWDW24
Model #WWDW45
Model #WWDW68
Steam-to-Water
Water-to-Water
Helitherm Indirect Heaters
Innovation Direct Fired Water Heaters
SmartPlate Heaters
U-Tube Double Wall Heaters
Model #SS1B+
Model #SS3CE+
Model #WS3E+
C-More Unit Controller
E8 Controller
Electronic Controls System
AERCO / ProtoNode Gateways
XPC Communications Gateway
BMS II Model 5R5-384
AERCO Control System (ACS)
Boiler Valve Controller
Modulex Pump Kits
X100 Corrosion Inhibitor
X200 Noise Reducer
X400 System Restorer
X500 Inhibited Antifreeze
AERCO Buffer Tanks
AERCO DHW Storage Tanks
Belimo F6 HDU Butterfly Motorized Valve
AERClean Air Filtration System
Communications Equipment
Condensate Neutralizer Kit
Hydraulic Separator
Optional Controls
Pump Products
Sentinel Hydronic System Products
Steam Traps
Tank Products
Valve Products
Boilers
Water Heaters
Clean Steam Generators
Integrated Controls
Accessories
Case Studies
Document Index
AERCO HydroSkrub
Benchmark Maintenance Kits
KC1000 Maintenance Kits
Modulex Maintenance Kits
Order/ Registration Form
FAQ's
Terms and Conditions
Direct Fired SST
SST Recertification
Modulex Boilers
End User
Maintenance
Equal 2 New Refurbishment Program
OnAER Remote Monitoring Service
Technical Training
O&M Manuals
Equipment Start-up & Registration
Extended Warranty Program
AERCO Technologies
AERCO Green Initiative
Importance of Modulation
Turndown vs. Valve Position
Condensing Flue Gases
Seasonal Performance
Comparing Efficiency
Self-Descaling Coil
Subcooling Steam
Rep Locator
Home
Markets
Products
Service & Support
Technologies
How to Buy
Connect with us
Home
>
Products
>
Boilers
>
Modulex Boilers
OVERVIEW
Modulex Boilers
A breakthrough in high-efficiency design, this line of condensing and fully modulating boilers supports 300,000 to 1 million Btu/hr. hydronic heating systems while delivering a greater degree or operating reliability for customer peace-of-mind.
Click here for video
Note:
AERCO Modulex Boilers are only available in North America.
FEATURES & BENEFITS
OPTIONS & ACCESSORIES
TECHNICAL DOCUMENTS & SPECIFICATIONS
MANUALS
CASE STUDIES
Condensing Boiler
Unmatched Turndown Up to 23:1 for MLX-1060
Whisper Quiet Operation Less than 50 dBa
Low NOx Emission <14ppm
Direct or Conventional Vent With PVC, CPVC or AL29-4C
Small, Doorway-Size Footprint From 42”H x 28”W x 27”D Up to 42”H x 49”W x 27”D
Flexible Piping & Venting
Optional Sealed Combustion
Superior Reliability
Cutaway view of two cast aluminum heat exchangers in a five module MLX-757.
Each thermal module has a burner viewport, igniter, flame detector and safety components.
Unique AERCO Controls
AERCO’s unique controls approach employs load sharing to maximize operating efficiency. After all thermal modules in a boiler come online, with each operating at its lowest firing rate (45,500 BTU/hr.), they continue to share the increasing load equally. All modules smoothly increase or decrease output in 1% increments to meet load changes.
A breakthrough in high-efficiency design, this line of condensing and fully modulating boilers supports 300,000 to 1 million Btu/hr. hydronic heating systems while delivering a greater degree or operating reliability for customer peace-of-mind.
To achieve the greatest possible fuel savings, each boiler combines independent, 151,500 BTU/hr. thermal modules that operate to deliver superior turndown and a range of non-cycling operation not readily achieved by competitive equipment or controls. Six units are available:
Min. Input
BTU/hr.
Max. Input
BTU/hr.
Max Output*
BTU/hr.
MLX - 303
45,500
303,000
260,000-279,000
MLX - 454
45,500
454,000
390,000-418,000
MLX - 606
45,500
606,000
521,000-558,000
MLX - 757
45,500
757,000
651,000-696,000
MLX - 909
45,500
909,000
781,000-835,000
MLX-1060
45,500
1,060,000
912,000-975,000
* Depending on Return Water Temperature
In addition to minimizing the redundant capacity needed for any project, these quiet and lightweight boilers can support low NOX and low gas pressure applications as well as PVC venting materials. Each unit enclosure offers multiple supply/return piping and venting locations for installation flexibility and allows for multiple units to be easily co-located for greater than 1 million Btu/hr. applications. Combustion view ports and easy access to all operating components further simplify minimal maintenance requirements.
Unmatched Operating Efficiency
Operating efficiency is influenced by the firing rate and return water temperature delivered to each Modulex boiler. The following chart outlines efficiency at 100% fire under BTS-2000 test conditions.
Thermal
Modules
Total
Turndown
Full-Fire
Efficiency
MLX - 303
2
6:1
92%
MLX - 454
3
10:1
92%
MLX - 606
4
13:1
92%
MLX - 757
5
16:1
92%
MLX - 909
6
20:1
92%
MLX-1060
7
23:1
92%
Revolutionary Design
Depending on unit size, each AERCO Modulex boiler contains between two and seven, pre-assembled thermal modules housed within a common enclosure. Each standalone, 151,500 BTU/hr. thermal module features:
a controller with built-in combustion safeguard;
a variable speed fan;
a modulating gas valve;
an electronic iginition with flame detector;
radiating, pre-mix, >3:1 modulating burner;
flow temperature sensor;
overtemperature limiting thermostat;
cast aluminum heat exchanger.
The operation of each 151,500 BTU/hr. thermal module is regulated by its own dedicated controller located internally along the front panel of the unit. Equipped with a combustion safeguard, each of these controllers drives the fan speed, gas delivery, burner turndown, etc. for its corresponding thermal module. All the individual thermal controllers are linked in a slave-to-master relationship with the boilerÂ’s master controller. It is the master controller which drives or bypasses one or more thermal modules based on the total system load and in response to operating feedback received from each thermal module controller.
Enhanced Efficiency & Reliabilty
The independent operation of two or more thermal modules increases each boiler's turndown range while also increasing its overall reliability. And since thermal efficiency increases as firing rates drop, the simultaneous low-fire operation of multiple modules also ensures that Modulex boilers continuously maximize operating efficiency.
For example, the MLX-1060 combines the power of seven thermal modules — each operating with greater than 3:1 turndown to deliver a 23:1 range of operations. From the low fire input of a single module (45,500 BTU/hr.) to the unitÂ’s full fire capacity (1,060,000 BTU/hr.), the boiler precisely matches load without cycling or temperature overshoot. Importantly, it does so by always employing as many modules as possible – each firing at its lowest possible firing rate. Less energy is required for the group of thermal modules, each firing at part load, to heat a building than if only some modules, each operating at full fire, carried the entire load. Consequently, this controls approach results in greater fuel savings than if each thermal module reached its full 151,500 BTU/hr. capacity before the next module came on line.
In the event that one module is not working correctly, the remaining modules – hence the boiler unit – will continue to operate. Independently operating thermal modules deliver built-in redundancy to the boiler through the availability of multiple combustion safeguards, burners, gas valves, blowers, etc. Such a design approach is unique in the industry and can significantly reduce the need for redundant system capacity.
Accessories
Modulex Pump Kits
: Specifically selected for hydronic heating, these pumps are ideal for the boiler loop pump of Modulex installations.
Hydraulic Separator
:
These hydraulic separators establish primary-secondary piping for Modulex boiler applications. Primary-secondary piping de-couples the boiler loop from the system loop — making it independent from system loop pressure fluctuations associated with opening/closing of zone valves or 3-way valves.
Sentinal Products
- Compatible with all materials found in a heating system, these chemicals offer overall protection of a heating system from sludge, scale, corrosion, and freeze conditions.
AERCO Condensate Neutralizer Kit
- is ideal for neutralizing condensate from condensing boilers and furnaces operating on natural gas or propane.
Literature & Performance Data
File Type
View
Save
File Type
View
Save
Pressure Drop Curves
.pdf
•
•
Altitude De-Rating Factor
.pdf
•
•
Modulex Family Brochure
.pdf
•
•
Modulex Technical Data Sheet
.pdf
•
•
Modulex Efficiency Curves
.doc
•
•
Sizing & Application Guidelines
File Type
View
Save
File Type
View
Save
Primary Loop Design Data
.pdf
•
•
Glycol Directive C401.0
.doc
•
•
Gas Supply Design Guide (GF-115-G)
.pdf
•
•
Electrical Power Guide (GF-115-E)
.pdf
•
•
Piping Guide (GF-115-PH)
.pdf
•
•
Venting Guide (GF-115-V)
.pdf
•
•
Controls Guide (GF-115-C)
.pdf
•
•
Product & Component Drawings
File Type
View
Save
File Type
View
Save
CSD-1 Manifold Assembly
.pdf
•
•
.dwg
•
•
Bill of Materials / Parts List (PL-A-153)
.pdf
•
•
.dwg
•
•
Dimensional Drawings
MLX-303H & MLX-454H
.pdf
•
•
.dwg
•
•
MLX-606H
.pdf
•
•
.dwg
•
•
MLX-757H
.pdf
•
•
.dwg
•
•
MLX-909H
.pdf
•
•
.dwg
•
•
MLX-1060H
.pdf
•
•
.dwg
•
•
3D Models
Modulex Revit Drawings
.rfa
•
•
Installation & Piping Drawings
File Type
View
Save
File Type
View
Save
Anchor Bolt Location
.pdf
•
•
.dwg
•
•
Clearance Drawing - Standalone
.pdf
•
•
.dwg
•
•
Clearance Drawing - Zero Side
.pdf
•
•
.dwg
•
•
Single Unit Installation
.pdf
•
•
.dwg
•
•
Single Unit Installation with DHW
.pdf
•
•
.dwg
•
•
Multi-Unit Installation - 2 Unit Side by Side
.pdf
•
•
.dwg
•
•
Multi-Unit Installation with DHW
.pdf
•
•
.dwg
•
•
Condensate Piping
.pdf
•
•
.dwg
•
•
Modulex Snowmelt System Installation with Injection Pump
.pdf
•
•
.dwg
•
•
Modulex Snowmelt System Installation with 4-Way Valve
.pdf
•
•
.dwg
•
•
Single Unit Installation with Hydraulic Separator
.pdf
•
•
.dwg
•
•
Multi-Unit Installation with Hydraulic Separator
.pdf
•
•
.dwg
•
•
Multi-Unit Installation with Hydraulic Separator & DHW
.pdf
•
•
.dwg
•
•
Single Unit Installation with Hydraulic Separator & DHW
.pdf
•
•
.dwg
•
•
Controls
File Type
View
Save
File Type
View
Save
Controls Guide (GF-115-C)
.pdf
•
•
Wiring
File Type
View
Save
File Type
View
Save
Internal Wiring
Internal Wiring Diagram
.pdf
•
•
Field Wiring
BCM Wiring Diagram - BAS to BCM
.pdf
•
•
Outdoor Reset
.pdf
•
•
.dwg
•
•
0-10 VDC Remote Setpoint
.pdf
•
•
.dwg
•
•
Domestic Water Heating
.pdf
•
•
.dwg
•
•
Specifications
File Type
View
Save
File Type
View
Save
MLX-303H
.doc
•
•
MLX-454H
.doc
•
•
MLX-606H
.doc
•
•
MLX-757H
.doc
•
•
MLX-909H
.doc
•
•
MLX-1060H
.doc
•
•
Certifications/Approvals
File Type
View
Save
File Type
View
Save
CSA Approval Letter
.pdf
•
•
SCAQMD Letter
.pdf
•
•
TCEQ Letter
.pdf
•
•
FAQ: Code Classifications for Modulex
.pdf
•
•
MEA Number Letter
.pdf
•
•
Warranty
File Type
View
Save
File Type
View
Save
Modulex Boiler Warranty
.pdf
•
•
Operation & Maintenance
File Type
View
Save
File Type
View
Save
Modulex High Pressure Manual (GF-115H)
.pdf
•
•
Modulex General Manual (GF-115)
.pdf
•
•
Controls
E8 Controls Guide (GF-115-C)
.pdf
•
•
Instructions
File Type
View
Save
File Type
View
Save
Modulex Users Guide (MUIM)
.pdf
•
•
Boiler Room Overhaul Cuts Fuel and Energy Usage for Graystone Corporation
Send to a Colleague
Your name:
Colleague's E-mail:
Your message (click here):
Please enter some message text.